{"id":20770,"date":"2023-07-27T11:23:33","date_gmt":"2023-07-27T04:23:33","guid":{"rendered":"https:\/\/marico.com.vn\/nclt-diesel-engine-water-treatment\/"},"modified":"2026-03-20T10:09:43","modified_gmt":"2026-03-20T03:09:43","slug":"nclt-diesel-engine-water-treatment","status":"publish","type":"product","link":"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/","title":{"rendered":"NCLT &#8211; Diesel Engine Water Treatment"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_58 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title \" >N\u1ed9i dung b&agrave;i vi\u1ebft<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\" role=\"button\"><label for=\"item-69f4f7189b0b5\" ><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input aria-label=\"Toggle\" aria-label=\"item-69f4f7189b0b5\"  type=\"checkbox\" id=\"item-69f4f7189b0b5\"><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/#NCLT\" title=\"NCLT\">NCLT<\/a><ul class='ez-toc-list-level-3'><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/#DESCRIPTION\" title=\"DESCRIPTION\">DESCRIPTION<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/#APPLICATIONS\" title=\"APPLICATIONS\">APPLICATIONS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/#DIRECTION_FOR_USE_%E2%80%93_DOSAGE_GUIDE\" title=\"DIRECTION FOR USE &#8211; DOSAGE GUIDE\">DIRECTION FOR USE &#8211; DOSAGE GUIDE<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/marico.com.vn\/en\/products\/nclt-diesel-engine-water-treatment\/#PRODUCT_CHARACTERISTICS\" title=\"PRODUCT CHARACTERISTICS\">PRODUCT CHARACTERISTICS<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 data-path-to-node=\"2\"><span class=\"ez-toc-section\" id=\"NCLT\"><\/span><b data-path-to-node=\"2\" data-index-in-node=\"0\">NCLT<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-path-to-node=\"3\"><b data-path-to-node=\"3\" data-index-in-node=\"0\">Corrosion and scale inhibitor for closed circuit cooling water systems<\/b><\/p>\n<ul data-path-to-node=\"4\">\n<li>\n<p data-path-to-node=\"4,0,0\">Highly effective anodic inhibitor protecting both ferrous and non-ferrous metals<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"4,1,0\">Deposits a microscopic protective film and includes built-in pH buffering<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"4,2,0\">Controls hard scale formation without damaging seals, glands, or gaskets<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"4,3,0\">Compatible with all types of Glycol-based anti-freeze<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"4,4,0\">Nitrite, borate, and organics based formula suitable for all engine types<\/p>\n<\/li>\n<\/ul>\n<hr data-path-to-node=\"5\" \/>\n<h3 data-path-to-node=\"6\"><span class=\"ez-toc-section\" id=\"DESCRIPTION\"><\/span><b data-path-to-node=\"6\" data-index-in-node=\"0\">DESCRIPTION<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-path-to-node=\"7\">NCLT is a superior liquid inhibitor designed for closed re-circulating water systems. It forms a protective barrier on metal surfaces while maintaining optimal pH levels. Before treatment, sacrificial anodes (zinc\/magnesium) must be removed to prevent undesirable deposits. It is essential that the system is free of oil and existing scale before applying NCLT.<\/p>\n<hr data-path-to-node=\"8\" \/>\n<h3 data-path-to-node=\"9\"><span class=\"ez-toc-section\" id=\"APPLICATIONS\"><\/span><b data-path-to-node=\"9\" data-index-in-node=\"0\">APPLICATIONS<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-path-to-node=\"10\">Suitable for high and normal speed diesel engines and other closed cooling circuits. NCLT should be added at a point of high circulation; avoid adding directly to expansion tanks with low flow. It will gradually remove existing sludge, which may temporarily cloud the water until clarified by small-volume draining.<\/p>\n<hr data-path-to-node=\"11\" \/>\n<h3 data-path-to-node=\"12\"><span class=\"ez-toc-section\" id=\"DIRECTION_FOR_USE_%E2%80%93_DOSAGE_GUIDE\"><\/span><b data-path-to-node=\"12\" data-index-in-node=\"0\">DIRECTION FOR USE &#8211; DOSAGE GUIDE<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-path-to-node=\"13\"><b>Initial Dose:<\/b> 6 liters of NCLT per ton of cooling water. <b>Maintenance:<\/b> Maintain nitrite levels between 1500 &#8211; 2000 PPM NO2. Use the UNIMARINE NITRITE TEST SET for monitoring. If levels drop without leaks, bacteria contamination may be present. <b>Water Quality:<\/b> Chlorides should be below 100 PPM and Hardness below 180 PPM CaCO3.<\/p>\n<hr data-path-to-node=\"14\" \/>\n<h3 data-path-to-node=\"15\"><span class=\"ez-toc-section\" id=\"PRODUCT_CHARACTERISTICS\"><\/span><b data-path-to-node=\"15\" data-index-in-node=\"0\">PRODUCT CHARACTERISTICS<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table style=\"width: 67.3131%;\" data-path-to-node=\"16\">\n<thead>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><strong>Feature<\/strong><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><strong>Details<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><span data-path-to-node=\"16,1,0,0\"><b data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\">Appearance<\/b><\/span><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><span data-path-to-node=\"16,1,1,0\">Pale yellow liquid<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><span data-path-to-node=\"16,2,0,0\"><b data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\">Specific Gravity<\/b><\/span><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><span data-path-to-node=\"16,2,1,0\">1.2 (20\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><span data-path-to-node=\"16,3,0,0\"><b data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\">pH (1% solution)<\/b><\/span><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><span data-path-to-node=\"16,3,1,0\">13 &#8211; 14<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><span data-path-to-node=\"16,4,0,0\"><b data-path-to-node=\"16,4,0,0\" data-index-in-node=\"0\">UN Number<\/b><\/span><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><span data-path-to-node=\"16,4,1,0\">3287 (IMO Class 6.1)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.8668%; text-align: center;\"><span data-path-to-node=\"16,5,0,0\"><b data-path-to-node=\"16,5,0,0\" data-index-in-node=\"0\">Compatibility<\/b><\/span><\/td>\n<td style=\"width: 150.089%; text-align: center;\"><span data-path-to-node=\"16,5,1,0\">Compatible with nitrite\/borate-based treatments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>NCLT Corrosion and scale inhibitor for closed circuit cooling water systems Highly effective anodic inhibitor protecting both ferrous and non-ferrous metals Deposits a microscopic protective film and includes built-in pH buffering Controls hard scale formation without damaging seals, glands, or [&hellip;]<\/p>\n","protected":false},"featured_media":13030,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[826,824,823],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product\/20770"}],"collection":[{"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/comments?post=20770"}],"version-history":[{"count":2,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product\/20770\/revisions"}],"predecessor-version":[{"id":20922,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product\/20770\/revisions\/20922"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/media\/13030"}],"wp:attachment":[{"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/media?parent=20770"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product_cat?post=20770"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/marico.com.vn\/en\/wp-json\/wp\/v2\/product_tag?post=20770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}